Skip to main content
Menu ମେନୁ

WATER TREATMENT

Clean water. Every drop. Every day.

RO+UV purification, water softeners, iron removal, Sewage Treatment Plants, and rainwater harvesting — custom-designed for Odisha's water conditions.

Designed for Odisha water profiles

Odisha municipal supply can have TDS above 300–600 mg/L depending on the season and district. Borewell water in coastal and mining-belt areas often carries iron, fluoride, and elevated hardness. A one-size-fits-all filter will not work — we test your source before recommending a system.

Commercial systems — hotels, hospitals, schools, factories — have regulatory obligations beyond the home. We design STP and ETP systems that meet Odisha Pollution Control Board Class A discharge standards and prepare the documentation for OPCB consent applications.

Our solutions

RO purification systems

Reverse osmosis membranes that remove dissolved solids, heavy metals, hardness, and nitrates. Sized from 10 L/hr (home) to 1,000+ L/hr (commercial).

UV disinfection

UV sterilisation that eliminates bacteria, viruses, and cysts — added to RO or as a standalone when TDS is within range but bacteriological contamination is a concern.

Water softeners

Ion-exchange softeners that remove calcium and magnesium hardness — extending the life of geysers, washing machines, and boilers significantly.

Iron & fluoride removal

Specific filter media for iron, manganese, and fluoride removal — common in borewell water across Khordha and Puri districts.

Sewage Treatment Plant (STP)

Biological treatment systems for domestic sewage at apartments, hotels, and institutions. OPCB-compliant. Treated water reused for flushing and gardening.

Rainwater harvesting

Roof collection, filtration chambers, and underground storage or recharge pits. Supplements 40–50% of non-potable water needs; improves borewell levels.

< 50 mg/L

TDS after RO treatment (from 600+ mg/L source)

99.99%

Bacteria elimination by UV stage

OPCB Class A

STP effluent discharge standard we design to

What every installation includes

  • Free source water quality test (TDS, hardness, iron, pH)
  • System sizing based on actual consumption
  • Installation and commissioning
  • First set of replacement filters included
  • As-built diagram and maintenance schedule
  • OPCB documentation support (commercial)
  • AMC with filter replacement reminders
  • 12-month workmanship warranty

For Government & Institutions

ସରକାର ଓ ସଂସ୍ଥା ପାଇଁ

M-Lite is RWS-empanelled and a government-approved contractor for public water infrastructure — community drinking water, school water supply, tribal-area systems, saline-to-normal treatment, and long-term pump O&M across Odisha.

M-Lite RWS ତାଲିକାଭୁକ୍ତ ଓ ସରକାରୀ ଜଳ ଭିତ୍ତିଭୂମି ପ୍ରକଳ୍ପ ପାଇଁ ଅନୁମୋଦିତ ଠିକାଦାର।

Community & school drinking water ସାମୁଦାୟିକ ଓ ବିଦ୍ୟାଳୟ ପାଇଁ ପାନୀୟ ଜଳ

Design, supply, and installation of drinking water systems for villages, Gram Panchayats, and schools. ଗ୍ରାମ, ପଞ୍ଚାୟତ ଓ ବିଦ୍ୟାଳୟ ପାଇଁ ପାନୀୟ ଜଳ ବ୍ୟବସ୍ଥା ଡିଜାଇନ, ଯୋଗାଣ ଓ ସ୍ଥାପନ।

Water supply in tribal areas ଆଦିବାସୀ ଅଞ୍ଚଳରେ ଜଳ ଯୋଗାଣ

Solar-powered water supply systems for remote and tribal habitations where grid power is absent. ବିଦ୍ୟୁତ ବିହୀନ ଦୁର୍ଗମ ଓ ଆଦିବାସୀ ଅଞ୍ଚଳ ପାଇଁ ସୌର ଜଳ ଯୋଗାଣ।

Saline-to-normal (brackish) water treatment ଲୁଣ ଜଳ ଶୋଧନ

Desalination and brackish water treatment plants for coastal and flood-prone areas — converting unusable water to safe drinking water. ଉପକୂଳ ଓ ବନ୍ୟା ଅଞ୍ଚଳ ପାଇଁ ଲୁଣ ଜଳ ଶୋଧ କ୍ଷଦ।

Pump maintenance & O&M contracts ପମ୍ପ ରକ୍ଷଣାବେକ୍ଷଣ ଓ O&M ଅନୁବନ୍ଧ

Long-term operation and maintenance contracts for government water supply infrastructure — scheduled visits, breakdown response, and reporting. ସରକାରୀ ଜଳ ଭିତ୍ତିଭୂମି ପାଇଁ ଦୀର୍ଘ ମ୍ୟାଦ O&M ଅନୁବନ୍ଧ।

See our public projects → ଆମ ସର୍ବସାଧାରଣ ପ୍ରକଳ୍ପ ଦେଖନ୍ତୁ →

System specifications

System Residential Commercial
RO capacity 10–75 L/hr 100–5,000 L/hr
UV output 11 W (25 L/hr) 55–120 W (100–500 L/hr)
Softener 15–50 L resin 100–1,000 L resin
STP capacity N/A 1 KLD – 500 KLD
Storage tank PVC, 500–2,000 L RCC / HDPE, custom
Discharge standard N/A OPCB Class A
Power requirement 25–60 W 250 W – 5 kW

FREQUENTLY ASKED

ବାରମ୍ବାର ପ୍ରଶ୍ନ

Questions we hear every day

ଆମ ଗ୍ରାହକ ପ୍ରତ୍ୟେକ ଦିନ ପଚାରନ୍ତି

BIS (IS 10500) specifies a desirable limit of 500 mg/L and a maximum permissible limit of 2000 mg/L. Odisha municipal supply often falls in the 200–600 mg/L range, but borewells in some districts can exceed 1000 mg/L with iron and fluoride contamination. We test your source water before recommending a system.

RO removes dissolved solids, heavy metals, and hardness but does not guarantee microbial sterility at all operating pressures. UV is added when the source has seasonal or consistent bacteriological contamination — common with borewell and open well sources. For municipal piped supply with regular chlorination, a standalone RO may suffice.

An STP (Sewage Treatment Plant) treats domestic sewage — biological waste from kitchens and bathrooms — for discharge or reuse. An ETP (Effluent Treatment Plant) treats industrial process wastewater containing chemicals, oils, or heavy metals. Both must meet Odisha Pollution Control Board (OPCB) discharge standards.

Yes. Any commercial or industrial installation generating over a certain volume of effluent requires OPCB consent-to-establish and consent-to-operate. We prepare the technical documentation for consent applications. All our STP designs meet OPCB Class A discharge standards.

Typically every 2–3 years for residential RO membranes, and every 1–2 years for commercial systems under higher load. Pre-filters (sediment and carbon) need replacement every 6–12 months. Our AMC plan includes filter replacement reminders and discounted parts.